| PLATING & PRINTED CIRCUIT |
Accessories and Replacement Parts
LCD Solid State Timer
|
- 24 hour display in either AM/PM or military
|
|
|
- Long-life lithium backup battery
|
| Model |
Volts |
Switching Capacity |
| ET-1 |
120 V
| 10 Amps |
| ET-2 |
240 V
| 10 Amps |
- Large LCD display
- Repeat 7 day timer with skp-a-day funciton
- Quartz driven time switch for high accuracy
- 9 On/Off settings per day
LCD Solid State Timer
(With Combination Controls)
 |
- 24 hour display in either AM/PM or military
|
|
|
- Long-life lithium backup battery
|
- Large LCD display
- Repeat 7-day timer with skip-a-day function
- Quartz driven time switch for high accuracy
- 9 On/Off settings per day

Magnetic Contactor
- Maximum voltage
600 volts
- Combine with base
temperature control for
larger amperage voltage
needs
- For On-Off control
- Call factory for
mercury contactors
| Model |
Voltage
1 or 3 pH
|
Coil
Voltage
|
Amps |
C101P2
C101P4
|
240
480
|
120 |
30 |
D101P2
D101P4 |
240
480
|
120 |
50 |
E101P2
E101P4 |
240
480 |
120 |
90 |
F101P2
F101P4 |
240
480 |
120 |
150 |
All 480V Contactors Require Auxiliary 120V Service Or A Step-Down
Transformer
TEFLON Sleeve
- Heat and chemical resistant FEP TEFLON*
sleeve
material supplied for all thermostat sensor
assemblies
- Various lengths available

NEMA 4X Enclosure
- Clear see through front panel
- Heavy duty hinge
- Corrosion resistant plastic
- Gasketed for moisture and fume tight enclosure
- Three sizes available: 6"x6", 8"x8",
10"x12"(15.2 cm x 15.2 cm, 20.3
cm x 20.3 cm, 25.4 cm x 30.4 cm)
- Latching hasp available

BubbleGard™ Probe Assembly
- Come complete with 6'/1.8 m of connector tubing &
mounting fixture
- Polypropylene standard construction
- TEFLON* probes optional
- Various lengths available
Fume Tight Fittings
- Corrosion resistant
plastic control box
connectors
| Model |
Description |
| FT-S |
Straight 1/2" (1.2 cm) Fitting
|
| FT-L |
90° F (32.2° C) Elbow
1/2" (1.2 cm) Fitting |
3/4" (1.905 cm) also available

Thermowell
- Protects thermostat
sensors
- Prevents floating
- Keeps sensor in right
location
- Eliminates errors in
temperature readings
Teflon
Model
|
PolyPro
Model
|
Length |
| WT-12 |
WPP-12 |
12"
(30.4 cm) |
| WT-24 |
WPP-24 |
24"
(60.9 cm) |
| WT-36 |
WPP-36 |
36"
(91.4 cm) |
Other lengths available
PVC Flexible Conduit 1/2" (1.27 cm)
& 3/4" (1.905 cm) I.D.
- Plastic corrosion and fume resistant conduit
- UL listed
- Various lengths available to 100 ft. (30.48 m) rolls
Smart Heater© Replacement Sensors
Retrofit sensors available to adapt CLEPCO heater products
to other brand installations. Consult factory.
| Model |
Leadwire |
Descriptions |
Amps |
| Option A |
2 Red |
One-time fuse, temperature under 200° F (93.3°
C) |
25 |
| Option AH |
2 Yellow |
One-time fuse, temperature over 200° F (93.3°
C) |
25 |
| Option B |
1 White, 1 Red, 1 Orange |
Dual bimetallic resetable assembly, temperature under
200° F (93.3° C) |
5 |
| Option T |
2 Red, 1 Green
(w/ Silver Element) |
One-time fuse, temperature under 180° F (82..2°
C) |
25 |
| Option E |
2 Blue |
Single bimetallic resetable assembly, temperature under
200° F (93.3° C) |
5 |

CRG95 Mechanism
- Complete with TEFLON*
sleeve on bulb &
capillary
| Model |
Sensor Assembly Length |
| M95 |
5.6' (1.7 m) Bulb and Capillary
|
"J" Thermocouple Sensor Separator
- For use with DRG200,
DRG160, C915 and C400
controls
- Complete with
TEFLON* sleeve
| Model |
Sensor Assembly Length |
| SJ10 |
10' (3.0 m) |
Other lengths available
DRG-165 Replacement Sensor
- Complete with
TEFLON* sleeve
| Model |
Sensor Assembly Length |
| S165 |
9.5' (2.8 m) |
QD50 & DRG50N4X Replacement Sensor
- Complete with TEFLON* sleeve
| Model |
Sensor Assembly Length |
| S50 |
8' (2.4 m) |

C915 Mechanism
- Non indicating solid
state replacement
mechanism.
- Sensor separate
| Model |
Temp. Range |
Max Amps |
Volts |
| M915 |
0 to 250 °F
(-17.7 to 121.1 °C) |
20 |
120/240 |
C400 Mechanism
- High temp range non
indicating solid
state replacement
mechanism
- "J" Thermocouple
sensor separate
| Model |
MAX
Temp.
Range |
Max Amps |
Volts |
M400
M400-R
|
0 to 400 °F
0 to 400 °F
(-17.7 to 204.4° C)
|
15
15
|
120/240
120/240
|
R- for cooling
|